Chat with us, powered by LiveChat
We rebranded from Bioevopeak to Infitek!

Zeta Potential and Nano Particle Size Analyzer, PSA-LS901

  1. Measurement Range: 0.3-10000 nm; -500mV to +500mV
  2. Concentration Range: 0.1 mg/mL-100 mg/mL (sample dependent)
  3. Electrophoretic Mobility Range: > ±20 μm·cm/(V·s)
  4. High-performance PMTs ensure a high SNR for photon signals

Share the product

Descrição

Applications

This product integrates zeta potential analysis and nanoparticle size testing. It is suitable for measuring the particle size and surface potential of various nanoemulsions, suspension colloids and other samples. It can be widely applied to nanomaterials in the fine chemical industry, as well as the R&D and production quality control of surfactants, oligomers and other materials. It also serves as a testing instrument for product development and quality control in industries such as inks and pharmaceutical preparations.

Features

  • Ultra-high-speed Data Acquisition

The core component of the instrument is the HA1024 digital correlator, which performs real-time acquisition of electrophoretic scattered light intensity and calculates the autocorrelation function; This accurately reflects the electrophoretic velocity of the particles, ensuring highly accurate Zeta potential measurements.

  • High Sensitivity and High Signal-to-Noise Ratio

Using professional-grade, high-performance photomultiplier tubes, the instrument delivers extremely high sensitivity and signal-to-noise ratio for photon signals.

  • High-Precision Constant Temperature Control

Using semiconductor temperature control technology, the instrument achieves temperature control accuracy up to 0.1 °C. This ensures that the sample remains at a constant temperature throughout the measurement process, preventing measurement deviations caused by temperature-induced changes in liquid viscosity and Brownian motion, thereby ensuring the accuracy and stability of the test results.

  • Stable Optical Path System

The optical path system constructed with the optical frequency shifting device and optical fiber coupling technology makes the detection system not only small in size but also strong in anti-interference capability, thus ensuring test stability.

Specifications

Model PSA-LS901
Measurement Range 0.3-10000nm (sample dependent) -500mV to +500mV
Concentration Range 0.1 mg/mL-100 mg/mL (sample dependent)
Electrophoretic Mobility Range > ±20 μm·cm/(V·s)
Maximum Conductivity 200 mS/cm (sample dependent)
Accuracy Error <1% (National standard sample D50 value) <15% (Standard sample)
Repeatability Error <1% (National standard sample D50 value) <15%(Standard sample)
Laser Source Semiconductor laser, λ = 635 nm, P = 1- 40 mW (adjustable)
Detector Photomultiplier tube
Scattering Angle 90° 18°
Sample Cell Volume 10 mm*10 mm*40 mm, 1-4mL 10 mm*10 mm*60 mm, 1mL
Temperature Control Range 5-90 °C
Temperature Control Accuracy ±0.1℃
Test Speed <5 min
Measured Parameters Nanoparticle size distribution, Zeta potential
Digital Correlator Model HA1024 HA1024
Auto-correlation Channels 892 892
Baseline Channels 4
Physical Channels 5000
Unit Delay Time 1µs-10ms (adjustable) 1µs-10ms (adjustable)
External Dimensions 560 mm*450 mm*300 mm
Net Weight 20kg

    Obtenha Cotações Agora!

    Normalmente entraremos em contato com você dentro de 24 horas. Você também pode nos ligar (+86-531-88982330) durante o horário comercial (8:30 às 17:45 UTC+8 de segunda a sábado) ou utilizar o chat ao vivo do site para obter uma resposta imediata.

    Contact Info

    Rm. 2014, Bldg. 3, Ligaoguojihuayuan, No. 1222, West Aoti Road, Lixia District, Jinan, Shandong

    Phone: +86-531-88982330

    Fax: +86-531-88983691

    Web: www.infitek.com

    Go to Top